The Secret Of Network-Appliance NS0-520 Prep

Our pass rate is high to 98.9% and the similarity percentage between our NS0-520 study guide and real exam is 90% based on our seven-year educating experience. Do you want achievements in the Network-Appliance NS0-520 exam in just one try? I am currently studying for the Network-Appliance NS0-520 exam. Latest Network-Appliance NS0-520 Test exam practice questions and answers, Try Network-Appliance NS0-520 Brain Dumps First.

Network-Appliance NS0-520 Free Dumps Questions Online, Read and Test Now.

NEW QUESTION 1

Exhibit.
NS0-520 dumps exhibit
The VMware ESX host discovers only two of four paths to a LUN on a new ONTAP cluster. Referring to the exhibit, which statement Is correct?

  • A. The fabric zoning configuration does not allow access to the target LlFs.
  • B. The igroup does not contain th
  • C. WWPN of one initiator.
  • D. The fabric name server is disabled.
  • E. The initiator HBA is not connected to the fabric.

Answer: D

NEW QUESTION 2

Click the Exhibit button.
NS0-520 dumps exhibit
You are implementing an ONTAP 9.5 AFF A300 SAN cluster with the NVMe, FC, and FCoE protocols. Referring to the exhibit, which three protocols and physical port pairs are supported? (Choose three.)

  • A. NVMe on ports 2a/2b
  • B. FC on ports 2a/2b
  • C. NVMe on ports 0e/0f
  • D. FCoE on ports 0e/0f
  • E. FC on ports 0e/0f

Answer: BCD

NEW QUESTION 3

You created a LUN in a new volume on your Netapp ONTAP cluster. You enabled the default snapshot schedule and enabled snapshot autodelete on the volume. In this scenario, in which three situations
does the snapshot autodelete feature automatically delete snapshot copies in the volume? (choose three)

  • A. The snapshot reserve space is nearly full
  • B. The LUN is nearly full
  • C. The overwrite reserve space is full
  • D. The volume is nearly full
  • E. The aggregate is nearly full

Answer: ACD

Explanation:
Depending on what is selected in the "Trigger" option, Snapshot Autodelete will automatically delete a snapshot when, either the volume space utilized, or the snapshot reserve reaches a threshold capacity
specified below.
Automatic deletion of Snapshot copies from flexible volumes Data ONTAP can automatically delete one or more Snapshot copies on the volume, provided the Data ONTAP Snapshot copy autodeletion
policy is enabled and set to trigger when the overwrite reserve is nearly full on the volume. You can find more information on this link:
https://kb.netapp.com/Advice_and_Troubleshooting/Data_Storage_Software/ONTAP_OS/How_to_use_Snapsh
https://library.netapp.com/ecmdocs/ECMP1217281/html/GUID-98FB8EC4-F3AE-4D25-AF44-E3200AFEB1A

NEW QUESTION 4

During maintenance of an AFF A250 node, you want to move the SAN LIFs that are members of a port set. In this scenario, which two statements are true? (choose two)

  • A. You must disable SLM for the node that hosts the LIF
  • B. You need to disable the zoning of the LIF WWPN
  • C. The LIF must be removed from the port set
  • D. You must take the SAN LIF offline

Answer: CD

Explanation:
If the LIF is a member of a port set, the LIF must have been removed from the port set before the LIF can be moved to a different node.
Change the status of the LIF to down (offline) You can find more information on this link:
https://docs.netapp.com/ontap-9/index.jsp?topic=%2Fcom.netapp.doc.dot-cm-sanag%2FGUID-09F5C2A3-FA6

NEW QUESTION 5

NS0-520 dumps exhibit
A customer needs to change ports 0e and 0f on AFF_1 to support FC.
Referring to the exhibit, which three steps are required to accomplish this task? (Choose three.)

  • A. Issue the ucadmin modify -node AFF_1 -adapter 0e -mode FC -type target command.
  • B. Issue the ucadmin modify -node AFF_1 -adapter 0e -mode FC -type initiator command.
  • C. Restart the FC service.
  • D. Take ports 0e and 0f offline.
  • E. Reboot the node.

Answer: BCD

NEW QUESTION 6

Exhibit.
NS0-520 dumps exhibit
Referring to the exhibit. What are two viable scenarios to test LUN multipathing on Host 1? (Choose two.)

  • A. Reboot one of the switches.
  • B. Disable one of the FC LIFs on Controller 1.
  • C. Disconnect one of the host cables.
  • D. Reboot Host 1.

Answer: AC

NEW QUESTION 7

Exhibit.
NS0-520 dumps exhibit
An administrator has an AFF A200 HA pair.
Referring to the exhibit, how many 10 Gbps connections would the customer have on a single node for SAN host connectivity?

  • A. 4
  • B. 6
  • C. 7
  • D. 2

Answer: A

NEW QUESTION 8

You have a 100GB volume with the space guarantee set to volume, This volume contains two space reserved 20 GB LUNs. Both LUNs are at 50% use. You then create a snapshot copy of the volume. No
modifications were performed since the snapshot copy was completed, and all actions were performed using the CLI. In this scenario, how much free space does the volume have?

  • A. 60 GB
  • B. 20 GB
  • C. 40 GB
  • D. 80 GB

Answer: A

Explanation:
Both LUN created are inheriting the space reserved parameter from its volume parent, so both LUNs are thick provisioned using 20 GB each one of them and the snapshots have not increased because
there has not been any changes since their creation 100GB - 20 GB - 20GB

NEW QUESTION 9

NS0-520 dumps exhibit
Referring to the exhibit, which two elements are required for NVMe host access with ONTAP 9.5 and using supported AFF nodes? (Choose two.)

  • A. You need 16 Gb FC HBAs installed in the AFF nodes.
  • B. You must have the license installed for NVMe support in the cluster.
  • C. You must have the license installed for FC support in the cluster.
  • D. You need 32 Gb FC HBAs installed in the AFF nodes.

Answer: CD

NEW QUESTION 10

A user cannot add more than one NVMe data LIF in ONTAP 9.4 on an SVM with a data protocol parameter set to nvme.
In this scenario, what is the problem?

  • A. The SVM data protocol should be set to FC.
  • B. The NVMe namespace is not created.
  • C. A demo license is used.
  • D. Only one NVMe data LIF can be configured per SVM.

Answer: B

NEW QUESTION 11

NS0-520 dumps exhibit
You have a performance critical database application that is running on a FAS9000 controller that uses FC. As shown in the exhibit, volume efficiency is enabled.
If you follow the performance recommendation, what are two results to the data in the volume? (Choose two.)

  • A. The new written data is compressed.
  • B. The new written data is uncompressed.
  • C. The existing data is uncompressed.
  • D. The existing data is compressed.

Answer: AC

NEW QUESTION 12

Exhibit.
NS0-520 dumps exhibit
You want to map a LUN to a server.
To which SAN object is the highlighted value in the exhibit added?

  • A. LUN
  • B. fabric zone
  • C. FlexClone
  • D. igroup

Answer: D

NEW QUESTION 13

You want to create an additional SVM from the System Manager GUI to serve data only using block-based protocols. You know the SVM name, the aggregate containing the root volume, and the required protocols.
What other information is required to successfully create this SVM?

  • A. name servers
  • B. SVM Management LIF network details
  • C. search domains
  • D. root volume security style

Answer: D

NEW QUESTION 14

After performing failover testing on a newly deployed MetroCluster configuration, some aggregates remain in a degraded state. Referring to the exhibit, which statement is true?
NS0-520 dumps exhibit

  • A. The MetroCluster Tiebreaker software is misconfigured
  • B. The ONTAP Mediator service is misconfigured
  • C. A cluster switch is powered off
  • D. A disk shelf is powered off

Answer: D

Explanation:
The aggregate with drives on the powered-off shelf should have a degraded RAID status, and drives on the affected plex should have a failed status
You can find more information on this link:
https://docs.netapp.com/us-en/ontap-metrocluster/install-ip/task_test_the_mcc_configuration.html#verifying-ope

NEW QUESTION 15

A customer recently added two nodes with FC ports to a 4-node cluster.
Which SVM configuration is needed before the customer creates LUNs on the new nodes?

  • A. The FC service needs to be enabled on the data SVM.
  • B. The existing LIFs need to be migrated to the new nodes.
  • C. New FC LIFs need to be created on the cluster SVM.
  • D. New FC LIFs need to be created on the new nodes.

Answer: D

Explanation:
Reference: https://docs.netapp.com/ontap-9/index.jsp?topic=%2Fcom.netapp.doc.exp-expand%2FGUID- E3BB89AF-6251-4210-A979-130E845BC9A1.html

NEW QUESTION 16

A customer experiences intermittent connectivity problems between an ESXi server and FC LUNs in an SVM. The customer has examined the nodes hosting the LUNs and both the disk and CPU performance are below 50% utilization. The customer examined the switch ports connected to the storage array, and they ate also below 50% utilization.
Which two steps would you perform next in this scenario? (Choose two.)

  • A. Verify that the host is using SnapDrive.
  • B. Verify that the host Ethernet interfaces are using jumbo frames.
  • C. Verify that the host recommended settings were applied by Virtual Storage Console.
  • D. Verify that the HBA queue depth is set properly.

Answer: CD

NEW QUESTION 17
......

Recommend!! Get the Full NS0-520 dumps in VCE and PDF From Thedumpscentre.com, Welcome to Download: https://www.thedumpscentre.com/NS0-520-dumps/ (New 234 Q&As Version)