NEW QUESTION 1
You have a Cisco UCS Fabric Interconnect that connects to upstream switches via four 10-Gbps port channels. You have a fully populated Cisco UCS B-Series Blade Server chassis that has a UCS-IOM 2208XP installed and uses all of the ports for the blade servers. What is the oversubscription ratio between the chassis and the upstream switch?
- A. 6:1
- B. 3:1
- C. 2:1
- D. 4:1
Answer: B
NEW QUESTION 2
What is the most common design requirement when creating a data center solution?
- A. high availability with disaster recovery
- B. multicore CPU servers
- C. traffic inspection for inbound traffic
- D. virtualization of network resources
Answer: A
NEW QUESTION 3
You plan to configure LISP between two data centers. Which two LISP components most be configured? (Choose two.)
- A. VTEP
- B. the site identifier
- C. a map resolver
- D. a map server
- E. VNI
Answer: CD
Explanation: http://www.cisco.com/c/en/us/td/docs/ios-xml/ios/iproute_lisp/configuration/xe-3s/irl-xe-3s-book/irl-cfg-lisp.ht
NEW QUESTION 4
A client require that direct attached storage be connected to the appliance port of the fabric interconnect. The storage and UCS manager subnets
To which UCS manager design point must you adhere to have communication between your server and the DAS?
- A. When a VSAN is created for an appliance port in the Appliances section of SAN, the same VSAN must not be created in the LAN cloud.
- B. When a VLAN is created for an appliance port in the Appliances section of LAN, the same VLAN must not be created in the LAN cloud.
- C. When a VSAN is created for an appliance port in the Appliances section of SAN, you must create the same VSAN in the SAN cloud.
- D. When a VLAN is created for an appliance port in the Appliances section of LAN, you must create the same VLAN in the LAN cloud.
Answer: D
NEW QUESTION 5
Which two options are goals of virtualization in the data center? (Choose two.)
- A. to provide automation for device deployment
- B. to provide resource isolation
- C. to automate the provisioning of VLANs
- D. to provide Integration between devices in a heterogeneous network
- E. to provide flexible resource management
Answer: CD
NEW QUESTION 6
Which statement accurately describes VSAN-based QoS when the same flow is present in two class maps that are associated to a policy map?
- A. The highest QoS value is used.
- B. The lowest QoS value is used.
- C. The QoS value of the class map that is attached first takes effect.
- D. The QoS value of the class map that is attached last takes effect.
Answer: C
Explanation: http://www.cisco.com/en/US/products/ps5989/products_configuration_guide_chapter09186a0080663141.html
NEW QUESTION 7
You must use one logical uplink for Fibre Channel traffic and Ethernet traffic on a Cisco UCS system. Which type of port should you use to accomplish this task?
- A. FCoE storage
- B. server
- C. FCoE uplink
- D. uplink
Answer: C
Explanation: Server and Uplink Ports on the Fabric Interconnect
Each fabric interconnect has a set of ports in a fixed port module that you can configure as either server ports or uplink Ethernet ports. These ports are not reserved. They cannot be used by a Cisco UCS instance until you configure them. You can add expansion modules to increase the number of uplink ports on the fabric interconnect or to add uplink Fibre Channel ports to the fabric interconnect.
You need to create LAN pin groups and SAN pin groups to pin traffic from servers to an uplink port. Each fabric interconnect can include the following types of ports:
Server Ports
Server ports handle data traffic between the fabric interconnect and the adapter cards on the servers.
You can only configure server ports on the fixed port module. Expansion modules do not include server ports.
Uplink Ethernet Ports
Uplink Ethernet ports handle Ethernet traffic between the fabric interconnect and the next layer of the network. All network-bound Ethernet traffic is pinned to one of these ports.
By default, Ethernet ports are unconfigured. However, you can configure them to function in the following ways:
Server
Uplink
FCoE
Appliance
You can configure uplink Ethernet ports on either the fixed module or an expansion module.
Uplink Fibre Channel Ports
Uplink Fibre Channel ports handle FCoE traffic between the fabric interconnect and the next layer of the network. All network-bound FCoE traffic is pinned to one of these ports.
By default, Fibre Channel ports are uplink. However, you can configure them to function as Fibre Channel storage ports. This is useful in cases where a Cisco UCS requires a connection to a Direct-Attached Storage (DAS) device.
You can only configure uplink Fibre Channel ports on an expansion module. The fixed module does not include uplink Fibre Channel ports.
NEW QUESTION 8
Which statement regarding network management for the data center is true?
- A. Flexible NetFlow can be used to provide enhanced network anomaly and security detection.
- B. The Network Analysis Module is best deployed in the core for highest visibility.
- C. NetFlow Support is available on most IOS and Nexus products, excluding the Nexus 1000v
- D. NetFlow Data Export is best positioned on the Nexus 5500 at the access or aggregation layer.
Answer: A
NEW QUESTION 9
Which two options are supported on Cisco UCS Fabric Interconnects that use native Fibre Channel connectivity? (Choose two)
- A. iSCSI
- B. NFS
- C. DAS
- D. SAN
- E. iFCP
Answer: CD
NEW QUESTION 10
Which two options are valid for Layer 3 connectivity between Cisco Nexus 1000V Series VSM and VEM? (Choose two.)
- A. an out-of-band management interface
- B. a dedicated control interface
- C. a virtual Ethernet interface
- D. a dedicated packet interface
- E. a VMware vCenter virtual machine virtual interface
Answer: AB
NEW QUESTION 11
Which three statements accurately describe end host mode on cisco UCS Fabric interconnect? (choose Three)
- A. The Fabric interconnect must be rebooted to enable end host mode
- B. Network to server unicast traffic is forward to the server only if the traffic arrived on pinned up link mode
- C. RPF and Deja -Vue checks apply to multicast traffic
- D. The uplink port are placed in rapid PVST+ edge trunk state
- E. Mac address learning occurs only on the server ports
- F. The vtp is enabled on fabric interconnect
Answer: ABE
NEW QUESTION 12
Which two characteristics are associated with the core layer of a Data Center Unified Fabric network? (Choose two.)
- A. Layer 2 default gateway redundancy
- B. QoS—policing
- C. no packet manipulation
- D. QoS—classification and queuing
- E. scalable routing protocols like OSPF
Answer: CE
NEW QUESTION 13
You deploy a new Cisco UCS system and use switching mode for storage communication. Which type of port should you configure as the interconnect to the SAN network?
- A. FCoE storage
- B. appliance
- C. server
- D. uplink
- E. FCoE uplink
Answer: E
NEW QUESTION 14
Which software runs on a device that is connected to a TrustSec-enabled port?
- A. Requester
- B. Authenticator
- C. Supplicant
- D. Authentication Proxy
Answer: C
NEW QUESTION 15
Refer to the Exhibit.
You need to allocate all interfaces on the same port ASIC to the same VDC. Which ports share an ASIC?
- A. ports 1-12
- B. ports 9-17
- C. ports 9-13
- D. ports 1-17
Answer: A
NEW QUESTION 16
You are configuring CIMC management IP pools. You need to avoid the following misconfigurations: Assigning an IP pool that contains only IPv4 addresses as the in-band IPv6 policy
Assigning an IP pool that contains only IPv6 addresses as the in-band IPv4 policy to a server CIMC What does a cisco recommend?
- A. Configure two separate in-band addresses pools that each have only IPv4 or IPv6 addresses
- B. Configure out-of-band management only for IPv6 and accept the default settings for IPv4
- C. Accept the default pool settings for both IPv4 and IPv6
- D. Configure out-of-band management only for IPv4 and accept the default settings for IPv6
Answer: A
NEW QUESTION 17
You must design a Cisco UCS Manager service profile for a customer. They require that the Cisco UCS blades utilize Cisco Discovery Protocol. Which policy must you add to the service profile template to meet this requirement?
- A. network control policies
- B. link protocol policies
- C. LAN connectivity policies
- D. flow control policies
Answer: A
NEW QUESTION 18
You are deploying a VM-FEX You have a VM that must be able to attach to a dynamic vNIC. Which action do you take on the VIC adapter?
- A. Dynamically configure the VIC adapter to connect to a vNIC.
- B. Configure a single vNIC only.
- C. Configure two static vNICs.
- D. Add the VIC adapter to a vNIC pool.
Answer: C
P.S. Easily pass 300-160 Exam with 132 Q&As Surepassexam Dumps & pdf Version, Welcome to Download the Newest Surepassexam 300-160 Dumps: https://www.surepassexam.com/300-160-exam-dumps.html (132 New Questions)