Cause all that matters here is passing the Network-Appliance NS0-592 exam. Cause all that you need is a high score of NS0-592 NetApp Certified Support Engineer - ONTAP Specialist exam. The only one thing you need to do is downloading Certleader NS0-592 exam study guides now. We will not let you down with our money-back guarantee.
Free NS0-592 Demo Online For Network-Appliance Certifitcation:
NEW QUESTION 1
What is a major difference between NFSv3 and NFSv4.x?
- A. NFSv4.x is stateful, and NFSv3 is stateless.
- B. NFSv4.x requires an auxiliary protocol for status monitoring, and NFSv3 does not.
- C. NFSv4.x is stateless, and NFSv3 is stateful.
- D. NFSv4.x requires an auxiliary protocol for mounting, and NFSv3 does not.
Answer: A
NEW QUESTION 2
In a 4-node cluster, nodes 1 and 2 are an HA pair, and nodes 3 and 4 are an HA pair. The following error appears in the log.
12/15/2018 15:48:47 node-2CRITICALclam.node.ooq: Node (name=node- 2, ID= 1001) is out of “CLAM quorum” (reason =quorum update).
In this scenario, which two statements are correct? (Choose two.)
- A. All LUNs are offline in the cluster.
- B. All LUNs are online in the cluster.
- C. Node 1 takes over node 2.
- D. Node 2 takes over node 1.
Answer: AC
NEW QUESTION 3
Click the exhibit button.
A customer is reporting that numbers in the statistics volume show command output appear to be incorrect. Referring to the exhibit, which statement is correct?
- A. The problem is due to a difference in operation size.
- B. Perfstat should be used to explain the behavior.
- C. There are operation types that are not listed in the output.
- D. A case with NetApp should be raised to find the root cause.
Answer: A
NEW QUESTION 4
Click the exhibit button.
Your customer added a new DS4246 shelf to their FAS system. They created an aggregate on the new shelf. Two weeks later, they log in to Active IQ and discover the Medium Impact error shown below.
“Both SAS connections from one controller go to the same shelf.” Referring to the exhibit, which statement is correct?
- A. You are unable to obtain a “Cable Visualization” overview from Active IQ.
- B. A faulty cable is causing the problem.
- C. A faulty IOM is causing the problem.
- D. You can correct this problem without downtime on the FAS system.
Answer: D
NEW QUESTION 5
Which statement is correct about the wafliron command?
- A. The wafliron command is used to correct parity inconsistencies.
- B. The wafliron command is used to correct inconsistent WAFL metadata.
- C. The wafliron command is used to correct WAFL i2p inconsistencies.
- D. The wafliron command is used to correct inconsistent user data blocks.
Answer: B
NEW QUESTION 6
For restore purposes, a storage administrator on an ONTAP system created a FlexClone of a volume that contains a LUN from a specific snapshot. This LUN cannot be seen by a Windows client after a disk rescan is performed by using Disk Management.
In this scenario, which statement is correct?
- A. The cloned LUN must be brought online.
- B. The cloned LUN needs to be mapped to an initiator group.
- C. The cloned volume must be split from the source volume before the LAN can be used.
- D. The cloned LUN must be renamed to a different name than the name of the source LUN.
Answer: C
NEW QUESTION 7
Click the exhibit button.
A customer reports that when they are failing over Hyper-V VMs, the process fails, and the server reports an error that indicates that there is something wrong with the storage.
Referring to the exhibit, which three actions would be required in ONTAP to solve this problem? (Choose three.)
- A. Verify that the -symlink-properties parameter is enabled on the share.
- B. Verify that the access-based-enumeration share parameter is configured.
- C. Verify that the continuously -available share parameter is configured.
- D. Verify that -offline-files parameter is set to manual on the share.
- E. Verify that the oplocks share property is configured.
Answer: BCE
NEW QUESTION 8
Click the exhibit button.
Your customer reports that their FAS2554A system reports multi-path HA when running the sysconfig command. However, Config Advisor reports an error about incorrect cabling.
What are the two reasons for the messages? (Choose two.)
- A. Shelves 10 and 20 have different IOM modules and must be in separate stacks.
- B. The FAS2554 system is cabled incorrectly to shelf ID 20.
- C. The DS2246 shelf is wrong; the shelf ID must be 11.
- D. Disk shelves 10 and 20 are cabled incorrectly to each other.
Answer: BD
NEW QUESTION 9
A customer complains that the copy offload does not work when copying large file from a Windows 8 client between the CIFS shares that are hosted on the same ONTAP cluster.
What are two reasons for this problem? (Choose two.)
- A. Deduplication is not enabled on the destination volume.
- B. The client should be using Windows 10 for ODX support.
- C. The source and target volumes reside on different cluster nodes.
- D. SMB 3.0 disabled on the CIFS SVM.
Answer: AD
NEW QUESTION 10
End users are complaining of high latency when accessing an ONTAP 9 luster.
Which command helps you to determine whether there is a storage component that is contributing to this problem?
- A. qos statistics performance show
- B. qos statistics latency show
- C. sysstat -c 30 -M 1
- D. wafltop show -v -cpu -I 10 -c 5-n 6
Answer: A
NEW QUESTION 11
A new cluster running ONTAP 9.5 has just been installed and you want to create a FlexGroup volume. Which action will accomplish this task?
- A. Use the storage pool create command.
- B. Use the volume create command.
- C. Use the Deploy utility to provision the FlexGroup volume.
- D. Use the volume size command.
Answer: A
NEW QUESTION 12
You are running a fabric-attached MetroCluster configuration with ONTAP 9.5software. There is a maintenance window for the upcoming weekend. Plexes in your mirrored aggregates between your two data centers have not been synchronizing for two days.
When the resynchronizations begin, they are not as quick as expected, and the process takes more than a day. You have been modifying the number of concurrent I/O streams using the storage raid-options modify raid.
resync.num_concurrent_ios_per_rg command, but the resynchronization speed stays slow.
You have four separate ISLs between your data centers using Brocade 6510 switches. Hardware problems are not an issue.
Which two actions should you take to prevent this problem in the future? (Choose two.)
- A. Update to at least ONTAP 9.4 software.
- B. Restart the resynchronizations after modifying storage raid-options modify raid.resync.num_concurrent_ios_per_rg command.
- C. Avoid changes on your aggregates during the maintenance window.
- D. Take the corresponding plexes offline before maintenance to avoid a base-level synchronization.
Answer: AB
NEW QUESTION 13
Click the exhibit button.
A volume move operation has been initiated to move a volume named MirrScr from one aggregate to another. The operation failed with the error that is shown in the exhibit.
In this scenario, which statement is correct?
- A. Manually trigger the cutover process in order to restart the job.
- B. The volume move cannot be completed at this time because of high use in this node.
- C. There are too many snapshots on the source volume.
- D. Cancel and restart the volume move operation.
Answer: A
NEW QUESTION 14
Click the exhibit button.
A customer has the ns-switch shown in the exhibit.
Which two statements are true in this scenario? (Choose two.)
- A. User names not present in the local database are looked up in LDAP.
- B. User mapping decisions are always based on the LDAP configuration.
- C. Host names are always resolved using the configured DNS server.
- D. Groups can be looked up both in the local database and in LDAP.
Answer: CD
NEW QUESTION 15
Which two statements are true about a data volume? (Choose two.)
- A. A data volume can be accessed by a LIF on any node.
- B. A data volume can be moved to any aggregate with space for it in the cluster.
- C. A data volume can be accessed by a user connected to any SVM.
- D. An SVM root or root load sharing mirror volume must be present on every node.
Answer: AB
NEW QUESTION 16
Click the exhibit button.

A storage administrator reports that when they enabled Vscan, they began receiving reports of CIFS users having very slow access to all their files. The storage administrator recovered from the issue by disabling Vscan on their SVM. The storage administrator was able to collect perfstat output during the time of the reported slow access, as shown in the exhibit.
In this situation, what is the problem?
- A. The problem is on the SVM, as shown in the scan_latency output.
- B. Vscan server 192.168.100.144 was slower than Vscan server 10.23.23.54 in completing Vscan requests.
- C. Vscan server 10.23.23.54 was slower than Vscan server 192.168.100.144 in completing Vscan requests.
- D. The problem was with both Vscan servers 192.168.100.144 and 10.23.23.54.
Answer: B
NEW QUESTION 17
A customer performs a takeover and giveback of their controllers and notices that several of their NFS clients lose access to their volumes for a short period of time during the SFO process. The customer reviewed the LIF failover policies, and the polices are correct.
What is the reason for this behavior?
- A. The clients are using NFSv4 to access the volumes.
- B. The export policies are incorrect and must be updated with node’s HA partner LIF information.
- C. A firewall is blocking the necessary network ports and needs to be updated to allow NFS communication.
- D. NFSv4 file locks need to be broken manually before initiating an SFO operation.
Answer: A
NEW QUESTION 18
A customer has created an interface group (igroup) named a0a, a VLAN named a0a-2500, and a data LIF associated with the VLAN interface that has been assigned an IP of 10.254.10.100. The customer is able to ping 10.254.10.100 from a Windows client without any issues, but data traffic is not working.
In this scenario, what is the solution to the problem?
- A. Disable flow control on the a0a interface.
- B. Configure an appropriate service policy for the data LIF.
- C. Correct the MTU mismatch between the broadcast domain configuration and the upstream network switches.
- D. Allow data traffic by using LIF firewall policies.
Answer: D
NEW QUESTION 19
A customer reports that a takeover has been disabled on an HA pair. What would be a cause for this to happen?
- A. The HA interconnect is not functioning properly.
- B. There is a disk running too hot.
- C. The interface for the hardware assist has become unavailable.
- D. The cluster network is not functioning properly.
Answer: A
NEW QUESTION 20
......
P.S. Allfreedumps.com now are offering 100% pass ensure NS0-592 dumps! All NS0-592 exam questions have been updated with correct answers: https://www.allfreedumps.com/NS0-592-dumps.html (65 New Questions)